Pyro MI Enhanced Grade Wiring Cable System

These cables are rated at 500V and are suitable for use where the voltage between the conductor and sheath and between conductors does not exceed 500V r.m.s. a.c. or 500V d.c.

 

Pyrotenax Part Code Description Outer Sheath
CC2L1 2 Core 1mm2 Pyro MI Light Duty Cable Bare Cable
CCM2L1 2 Core 1mm2 Pyro MI Light Duty Cable LSF Covered
CC2L1.5 2 Core 1.5mm2 Pyro MI Light Duty Cable Bare Cable
CCM2L1.5 2 Core 1.5mm2 Pyro MI Light Duty Cable LSF Covered
CC2L2.5 2 Core 2.5mm2 Pyro MI Light Duty Cable Bare Cable
CCM2L2.5 2 Core 2.5mm2 Pyro MI Light Duty Cable LSF Covered
CC2L4 2 Core 4mm2 Pyro MI Light Duty Cable Bare Cable
CCM2L4 2 Core 4mm2 Pyro MI Light Duty Cable LSF Covered
CCM3L1 3 Core 1mm2 Pyro MI Light Duty Cable LSF Covered
CC3L1.5 3 Core 1.5mm2 Pyro MI Light Duty Cable Bare Cable
CCM3L1.5 3 Core 1.5mm2 Pyro MI Light Duty Cable LSF Covered
CC3L2.5 3 Core 2.5mm2 Pyro MI Light Duty Cable Bare Cable
CCM3L2.5 3 Core 2.5mm2 Pyro MI Light Duty Cable LSF Covered
CCM4L1 4 Core 1mm2 Pyro MI Light Duty Cable LSF Covered
CC4L1.5 4 Core 1.5mm2 Pyro MI Light Duty Cable Bare Cable
CCM4L1.5 4 Core 1.5mm2 Pyro MI Light Duty Cable LSF Covered
CC4L2.5 4 Core 2.5mm2 Pyro MI Light Duty Cable Bare Cable
CCM4L2.5 4 Core 2.5mm2 Pyro MI Light Duty Cable LSF Covered
CCM7L1 7 Core 1mm2 Pyro MI Light Duty Cable LSF Covered
CC7L1.5 7 Core 1.5mm2 Pyro MI Light Duty Cable Bare Cable
CCM7L1.5 7 Core 1.5mm2 Pyro MI Light Duty Cable LSF Covered
CC7L2.5 7 Core 2.5mm2 Pyro MI Light Duty Cable Bare Cable
CCM7L2.5 7 Core 2.5mm2 Pyro MI Light Duty Cable LSF Covered

 

Standards and Approvals

Cables
Pyro Mi Wiring Cables are manufactured, tested and LPCB approved to BS EN 60702-1. Pyro Mi Wiring Cables are LPCB approved to BS 8434-2, BS 5839-1 Clause 26.2 (Enhanced) and BS EN 50200 Class PH 120. BS 8434- Methods of test for assessment of the fire integrity of electric cables Part 1: Test for unprotected small cables for use in emergency circuits - BS EN 50200 with the addition of water spray. Part 2: Test for unprotected small cables for use in emergency circuits - BS EN 50200 with a 930°C flame and with water spray. BS 6387 - 1994 Performance Requirements for Cables Required to Maintain Circuit Integrity under Fire Conditions Categories C, W and Z. IEC 60331- Tests for Electric Cables under fire conditions. Underwriters Laboratories- UL2196-USA, ULC-S139-Canada. Tests for fire resistant cables. London Underground- Fire Survival Cable (MICC) EME-SP-14-028-A1.

Pyrotenax MI Terminations
Pyro MI Terminations are tested in accordance with BS EN 60702: Part 2: Pyro MI Terminations are Certified for use in potentially explosive atmospheres. Glands - BASEEFA 03ATEX0347X. Increased Safety Seals - BASEEFA 02ATEX0194U.